Self Priming Sewage Water Pump with Ce Certificate

Product Details
Customization: Available
Max.Head: >150m
Max.Capacity: >400 L/min
Manufacturer/Factory, Trading Company
Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001
  • Self Priming Sewage Water Pump with Ce Certificate
  • Self Priming Sewage Water Pump with Ce Certificate
  • Self Priming Sewage Water Pump with Ce Certificate
  • Self Priming Sewage Water Pump with Ce Certificate
  • Self Priming Sewage Water Pump with Ce Certificate
  • Self Priming Sewage Water Pump with Ce Certificate
Find Similar Products

Basic Info.

Model NO.
ZW
Impeller Number
Single-Stage Pump
Working Pressure
High Pressure Pump
Influent Type of Impeller
Single Suction Pump
Position of Pump Shaft
Horizontal Pump
Pump Casing Combined
Horizontal Split Pumps
Mounting Height
Since Irrigation Centrifugal Pumps
Impeller
Open
Usage
Pumps
Size
2 Inch to 12 Inch
Drive Mode
Electric Motor and Diesel Engine
Transmission Type
Direct Connection and Belt Pulley Connection
Seal
Mechanical Seal
Material
Cast Iron, Stainless Steel etc.
Description
Clean Water Pump
Solids Handling Capacity
Non-Clog
Application
Agriculture, Irrigation, Wastewater Treatment etc.
Flow Rate
8m3/H-1275m3/H
Transport Package
Export Polywood Case
Specification
CE, SGS, ISO9001
Trademark
Sundream
Origin
Shanghai
HS Code
8413709990
Production Capacity
100000 PCS/Year

Product Description

We are professional manufacturer for Clean water pump, with high and stable quality, and we have made many water pump solutions for many customers.

Overview:
ZW Self Priming water Pump is a new structure product which is developed on base of reaping study of domestic and foreign similar technology. Pump of this kind has features of simple structure, good self priming performance and high sewage capability, high efficiency and energy saving, convenient usage and maintenance etc compared with domestic similar product. And it belongs to the first creation in the country at sewage pump series. All technology and performance indexes are on top of the nation, reaching the international advanced level. So it has the wide application market and developing future.

Self Priming water Pump Application:
This kind of pump combines self priming and non-clogging, adopting axial circumfluence outer-mix type. And through the particular design of case and impeller channel, it not only needn't to be fixed with base valve and poured in water like normal self priming, but also can suck and discharge liquid contain-ing big grain and long fibrin substance. So it is widely used in municipal sewage project, river and pond breeding, light industry, papermaking, weaving, foodstuff, chemical industry, power industry, fibrin, slurry and mixed suspension etc chemical medium.
Operating condition:
1. Surrounding temperature <50degree, Medium temperature<80 degree
2. Medium consistency should not exceed 1240kg/m. 3
3. Self priming height should not exceed the stated number of 4.5-5.5meters, and the suction pipe should not be over 10 meters long.
4. It can pass the suspended grain whose diameter is 60 percent of pump caliber, and the fibrin which is 5 times long of pump caliber.
5. PH range of liquid: 6-9 (For cast iron pump), 2-13 (For stainless steel pump)

Brief introduction:
This kind of pump combines self priming and non-clogging, adopting axial circumfluence outer-mix type. And through the particular design of case and impeller channel, it not only needn't to be fixed with base valve and poured in water like normal self priming, but also can suck and discharge liquid contain-ing big grain and long fibrin substance. It has features of simple structure, good self priming performa-nce and high sewage capability, high efficiency and energy saving, convenient usage and maintenance etc compared with domestic similar product. And it belongs to the first creation in the country at sewage pump series. It can well match diesel engine to improve the working efficiency greatly.
Structure:
ZW series self priming non-clogging sewage pump consists of pump body, impeller, back cover, me-chanical seal, pump shaft, bearing seat, inlet valve, air-liquid separate pipe, water valve, inlet and outlet connection pipe etc.

Working principle:
Deposit liquid chamber is designed in pump body. It and back flow hole upside and circulation hole down connect working chamber of pump. They become axial circumfluence outer-mix system...Some liquid has deposited inside of pump when pump stops. When pump starts, the deposit liquid with air throws up out under the effect of impeller. Liquid goes back to working chamber by the gridding of air-liquid separate pipe and air is discharged out of pump. Meanwhile pump body inside becomes vacuum and it realizes self priming performance.

For more detailed specification and performance data, please contact us directly by email or call.
specification and performance parameter
Model Capacity(m3/H) Head (M) Power(KW) Rotary speed(rpm) Efficiency  %
ZW65-30-18 30 18 4 1450 45
ZW80-40-16 40 16 4 1450 50
ZW100-100-15 100 15 7.5 1450 50
ZW100-80-20 80 20 7.5 1450 53
ZW100-100-20 100 20 11 1450 53
ZW125-120-20 120 20 15 1450 55
ZW150-180-14 180 14 15 1450 60
ZW150-180-20 180 12 22 1450 60
ZW200-280-14 280 14 22 1450 65
ZW200-280-28 280 28 55 1450 55
ZW250-420-20 420 20 55 1450 61
ZW300-800-14 800 14 55 1450 65
for more detailed specification and performance data , please contact us directly by email or call.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier